Construction Double robe hook shall be surface-mounted fabricated of type-304 stainless steel with satin finish. Flange and support arm shall be 22-gauge and equipped with a concealed, 18-gauge mounting bracket that is secured to a concealed, 19-gauge wall plate with a stainless steel setscrew. Cap shall be 14-gauge, welded to the support arm.
Installation To remove concealed wall plate from back of flange and mounting bracket, loosen setscrew. Mount wall plate so prongs are at top; secure with two sheet-metal screws, furnished by manufacturer, at points indicated by an S. Engage mounting bracket onto prongs of wall plate, then secure into position by tightening setscrew at bottom of flange.
For partitions with particle-board or other solid core, secure with sheet-metal screws furnished, or provide through-bolts, nuts, and washers
For hollow-core metal partitions, provide solid backing into which the furnished sheet-metal screws can be secured.
For plaster or drywall construction, provide concealed backing to comply with local building codes, then secure unit with sheet-metal screws furnished.